Deutz — Deutz 2011 Workshop Manual Level 3

Fuel system W 07-07-05 2011 Note After cleaning, a used injection valve must buzz audibly and atomize the fuel finely when the lever is actuated quickly . The injection nozzle must be changed if it does not buzz after cleaning. The jet profile may deviate considerably from that of a new injection valve. Caution! The pressure in the spring space must be relieved in any case before installing the injection valves. 6 ! z Loosen the nozzle clamping nut with the long socket approx. 180° (relieve pressure) and re-tighten. 07002 z Install injection valves О Job card W 07-07-01 . 0312 1600 - 0138 5/6 © 11/2004 © 36296 1 © 36296 1 © 39486 1 © 39486 1