MID 128-SID 33 MID 128-SID 33 MID 128 SID 33 — COOLING FAN CONTROL Additional Symptoms: Higher than normal coolant temperatures, poor air conditioning performance or lower than normal coolant temperatures may be experienced. Failure Mode Identifier (FMI): 3 (Voltage Above Normal, or Shorted To High Source), 4 (Voltage Below Normal, or Shorted To Low Source), 5 (Current Below Normal or Open Circuit) If a customer complains that the fan clutch does not disengage and code SID 33 has not been logged in the EMS Module, the problem may be due to a mechanical failure in the chassis air system. Parameter Identification (PID): S33 Message Identification (MID): 128 Circuit Description (On/Off Fan):
The Fan Clutch Solenoid controls the operation of the cooling fan by using a solenoid. The Fan Clutch Solenoid is supplied battery voltage and is grounded by the Engine Management System (EMS) Module. When the EMS System Module determines fan operation is needed, based on coolant temperature, intake air temperature or A/C load, the EMS Module will de-energize the Fan Clutch Solenoid allowing the fan clutch to engage. The fan can engage without warning. Hands, arms and personal items can easily be entangled in the belts or fan blades. Keep arms, hair, clothing, jewelry, etc. clear from the fan and belts when the engine is running. FMI 3 Circuit Description (Electronic Viscous Fan):
The Electronic Fan Drive contains a solenoid that controls the flow of fluid between reservoirs in the fan drive housing and cover. The EMS Module provides power to the solenoid and controls solenoid operation to optimize fan speed, based on coolant temperature, intake air temperature and A/C load. Voltage Above Normal, or Shorted To High Source Conditions for fault code: Short to positive in the Cooling Fan control circuit Possible causes: Location: The On/Off Fan Clutch Solenoid is located on the lower left side of the radiator shroud. The Electronic Fan Drive is bolted to the drive pulley on the front of the engine.
Broken Cooling Fan Actuator Faulty Cooling Fan Actuator harness or connector Code Setting Conditions: When the Engine Management System (EMS) Module detects there is a short to voltage in the cooling fan control circuit, FMI 3 will set and the fan will operate continuously. When there is a short to ground, FMI 4 will set and the fan will not operate. If there is an open circuit, FMI 5 will be set and the fan will operate continuously. Reaction from Engine Management System (EMS) Module: Fan runs at full speed Increased fuel consumption Noticeable external symptoms: MIL lamp illuminated If code SID 33 sets with FMI 4, there may be additional active codes.
If this is the case, follow the diagnostic procedures for the other codes first, then check to make sure code SID 33 is no longer active. Page 113 MID 128-SID 33