MID 140-PID 96 MID 140-PID 96 MID 140 PID 96 — FUEL LEVEL FMI 6 Current Above Normal or Grounded Circuit Failure Mode Identifier (FMI): 5 (Current Below Normal or Open Circuit), 6 (Current Above Normal or Grounded Circuit) Conditions for fault code: Circuit shorted to ground Parameter Identification (PID): P96 Sensor resistance below 20 Ohm Message Identification (MID): 140 Circuit Description: The fuel level sensor is a variable resistor called a potentiometer. The resistance through the sensor changes as the fuel level changes. Possible causes: Faulty harness Faulty sensor Faulty fuel level sensor Location: The fuel level sensor is located in the fuel tank.
Reaction from Instrument Cluster Module (ICM): FMI 5 Electronic malfunction lamp is illuminated Current Below Normal or Open Circuit Noticeable external symptoms: Gauge needle moves to zero position Conditions for fault code: Abnormally low current Open circuit Possible causes: Sensor resistance above 1 kOhm Faulty harness Faulty sensor Faulty fuel level sensor Reaction from Instrument Cluster Module (ICM): Electronic malfunction lamp is illuminated Noticeable external symptoms: Gauge needle moves to zero position Page 124 MID 140-PID 96