Mack Trucks V-MAC IV — Mack Trucks V-MAC IV — спецификация (EN)

MID 140-PID 177 MID 140-PID 177 MID 140 PID 177 — TRANSMISSION OIL TEMPERATURE FMI 6 Current Above Normal or Grounded Circuit Failure Mode Identifier (FMI): 5 (Current Below Normal or Open Circuit), 6 (Current Above Normal or Grounded Circuit), 9 (Abnormal Update Rate) Conditions for fault code: Circuit shorted to ground Sensor resistance below 10 Ohm Parameter Identification (PID): P177 Possible causes: Faulty harness Message Identification (MID): 140 Faulty sensor Circuit Description: The temperature sensor is a thermistor. The resistance of the sensor changes inversely to the temperature of the transmission oil. When the temperature is cold, the sensor resistance is high.

As the temperature of the transmission oil increases, the sensor resistance decreases. The Instrument Cluster Module (ICM) monitors the voltage drop across the temperature sensor. Reaction from Instrument Cluster Module (ICM): Electronic malfunction lamp is illuminated Noticeable external symptoms: Gauge needle moves to zero position FMI 9 Location: The transmission oil temperature sensor is located inside of the transmission. Abnormal Update Rate FMI 5 Conditions for fault code: Expected Transmission Electronic Control Unit (TECU) message(s) not received Current Below Normal or Open Circuit Possible causes: Conditions for fault code:

J1939 communication down Open circuit Faulty harness Sensor resistance above 70 kOhm Faulty transmission electronic control unit Possible causes: Reaction from Vehicle Electronic Control Unit (VECU): Faulty harness Faulty sensor Electronic malfunction lamp is illuminated Reaction from Instrument Cluster Module (ICM): Noticeable external symptoms: Electronic malfunction lamp is illuminated N/A Noticeable external symptoms: Gauge needle moves to zero position Page 133 MID 140-PID 177