MID 128-PID 153 MID 128-PID 153 MID 128 PID 153 — CRANKCASE PRESSURE Reaction from Engine Management System (EMS) Module: Failure Mode Identifier (FMI): 0 (Data valid but above normal operational range), 1 (Data valid but below normal operational range), 2 (Data erratic, intermittent or incorrect), 3 (Voltage above normal or shorted to high source), 5 (Current below normal or open circuit) MIL lamp illuminated Noticeable external symptoms: N/A FMI 2 Data erratic, intermittent or incorrect Parameter Identification (PID): P153 Conditions for fault code: Message Identification (MID): 128 Plausibility FMI 0 Possible causes:
Data valid but above normal operational range The crankcase pressure is showing either too high or too low value (abnormal value) Conditions for fault code: Out of range, max voltage, illegal Reaction from Engine Management System (EMS) Module: Critically Above Range Possible causes: MIL lamp illuminated The non-filtered pressure difference (between crankcase pressure and ambient air pressure) is/was above limit. (The fault code will remain during the entire driving cycle (unless reset) Noticeable external symptoms: N/A FMI 3 Voltage above normal or shorted to high source Reaction from Engine Management System (EMS) Module: Conditions for fault code:
MIL lamp illuminated Short Circuit+, Measuring line Open Circuit, Ground line Noticeable external symptoms: Forced idle Possible causes: Engine shut down Crankcase Pressure Sensor failures Faulty harness FMI 1 Reaction from Engine Management System (EMS) Module: Data valid but below normal operational range Conditions for fault code: MIL lamp illuminated Out of range, min voltage, illegal Noticeable external symptoms: Possible causes: N/A Crankcase Pressure Sensor out of range Page 40 MID 128-PID 153