MID 128-PSID 47 MID 128-PSID 47 MID 128 PSID 47 — PARTICULATE TRAP REGENERATION Reaction from Engine Management System (EMS) Module: MIL lamp illuminated Failure Mode Identifier (FMI): 0 (Data valid but above normal operational range), 1 (Data valid but below normal operational range), 7 (Mechanical System Not Responding or Out Of Adjustment), 8 (Abnormal frequency, pulse width or period), 12 (Bad Intelligent Device or Component) Noticeable external symptoms: Regeneration not possible FMI 7 Mechanical System Not Responding or Out Of Adjustment Parameter Identification (PID): P47 Conditions for fault code: Message Identification (MID):
128 Mechanical problem FMI 0 A1 sensor goes above 1004 degrees F (540 degrees C) Data valid but above normal operational range Possible causes: Exhaust pipe disconnected before Diesel Particulate Filter (DPF) Conditions for fault code: Plausability, too high Reverse exhaust flow out of DPF Regeneration active Reaction from Engine Management System (EMS) Module: Possible causes: Faulty After Treatment Injector MIL lamp illuminated Reaction from Engine Management System (EMS) Module: Noticeable external symptoms: MIL lamp illuminated Aborted and ceased regeneration Regeneration not possible Noticeable external symptoms:
Regeneration not possible FMI 8 Abnormal frequency, pulse width or period FMI 1 Conditions for fault code: Data valid but below normal operational range Regeneration period too long Conditions for fault code: Possible causes: Plausability, too low N/A Regeneration active Reaction from Engine Management System (EMS) Module: Possible causes: Faulty After Treatment Injector MIL lamp illuminated Faulty Diesel Particulate Filter (DPF) catalyst Noticeable external symptoms: N/A Page 73 MID 128-PSID 47