Deutz — 5.1.2 LIST OF ALARMS BY STANDARD CODE

5. ALARMS 5.1 LIFT AND ASM CONTROL UNIT ALARMS 5.1.2 LIST OF ALARMS BY STANDARD CODE Example of flash for code 23 (times expressed in seconds). ON OFF 0,5 0,5 0,5 1,5 0,5 0,5 0,5 0,5 0,5 3,0 20-46 Standard flash Extended flash Display on ART Description Page. 11 21 ShortCircuitEVUP The control unit detects that the lift Up control solenoid valve is short-circuiting. 20-55 23 EvUpNotConnect.L The control unit detects, in the absence of any energizing signal (static safety), that the lift Up solenoid valve coil is not connected. 20-56 24 EvUpNotConnect.D The control unit detects, in the presence of an energizing signal (dynamic safety), that the lift Up solenoid valve coil is not connected.

20-57 12 31 ShortCircuitEVDW The control unit detects that the lift Down control solenoid valve is short-circuiting. 20-58 33 EvDwDeconnecteeL The control unit detects, in the absence of any energizing signal (static safety), that the lift Down solenoid valve coil is not connected. 20-59 34 EvDwDeconnect.D The control unit detects, in the presence of an energizing signal (dynamic safety), that the lift Down solenoid valve coil is not connected. 20-60 13 13 ShortCircuitPWM The control unit detects a short circuit on the control line to the lift directional control valve. 20-51 16 68 8v Supply The control unit detects that the 8V power input is not correct. 20-69 18 16 HitchControlLev.

The control unit detects incorrect data coming from the lift control lever. 20-53 22 18 Pos.Sens.NotConn The control unit detects that the lift position sen- sor is not connected. 20-54 23 72 SetPoint Potent. The control unit detects that the depth potenti- ometer is disconnected or short-circuiting. 20-71 24 74 MaxHeightPotent. The control unit detects that the maximum lift height potentiometer is disconnected or short- circuiting. 20-73 26 12 Supply Pos. Sens. The control unit detects that the power input to the lift position sensor is not correct. 20-50 67 5v Supply The control unit detects that the 5V power input is not correct. 20-69 31 62 NoRightDraftSens.

The control unit detects that the right hand draft sensor is disconnected. 20-65 32 63 NoLeftDraftSens. The control unit detects that the left hand draft sensor is disconnected. 20-66