5. ALARMS 5.1 LIFT AND ASM CONTROL UNIT ALARMS Extended alarm: 31 ShortCircuitEVDW Standard alarm: 12 DESCRIPTION The control unit detects that the lift Down solenoid valve is short-circuiting. CHECK Check that the contacts on connector “EV DW” and on those of the lift control unit, “JX1” and “JX2”, are firmly attached and not oxidised. Test the internal resistance of the lift Down control solenoid (for details, see section 40). With the starter key in the “O” (OFF) position, connect a test meter to pin 1 of connector “EV DW” and to chassis earth, and measure the resistance to check for short circuits to earth (meter reading: infinity).
Clear all alarms, turn the starter key first to “O” (OFF) and then back to the “I” (ON) position again, and if the alarm is still present, the control unit must be renewed. 20-58 0.012.8732.4 5 4 2 20 4 5 20 2 JX1 GND4 J2 TKAB2 5 2 F34 7.5A +15 0441.9533 19 GND2 EV DW 2 1 0.012.8672.4 D0017601 4 5 20 2 GND4 5 2