Deutz — 5.1.4 ANALYSIS OF LIFT AND ASM ALARMS

5. ALARMS 5.1 LIFT AND ASM CONTROL UNIT ALARMS Extended alarm: 41 ShortCircuit4WD Standard alarm: 51 DESCRIPTION The control unit detects that the 4WD clutch solenoid valve relay is short-circuiting. NOTE This alarm will be displayed only when ASM is active. CHECK Check that the contacts of relay “RL9” and of the connectors on the lift control unit, “JX1” and “JX2”, are firmly attached and not oxidised. Deselect the four wheel drive, differential lock and ASM functions with the relative switches and, with the starter key in the “I” (ON) position, connect a test meter to pin 1 and pin 2 of the relay socket and check the voltage, which should measure 2.5 V approx.

With the starter key in the “O” (OFF) position, connect a test meter to pin 1 and pin 2 of the relay socket and measure the resistance to verify that there are no short circuits (meter reading: infinity). Replace the relay “RL9” with a new one, clear all alarms, turn the starter key first to “O” (OFF) and then back to the “I” (ON) position again, and if the alarm is still present, the control unit must be renewed. 0.012.8732.4 5 4 8 20 JX2 8 GND4 J2 7.5A GND4 F34 D7 +15 3 4 5 1 2 RL9 (DT/BRAKE) 0441.9533 D0017740 20-61 5 20 2 8