5. ALARMS 5.1 LIFT AND ASM CONTROL UNIT ALARMS Extended alarm: 51 ShortCircuitDIF -OK - Standard alarm: 52 DESCRIPTION The control unit detects that the differential lock actuator solenoid valve is short-circuiting. CHECK Check that the contacts on connector “EV DF” and on those of the lift control unit, “JX1” and “JX2”, are firmly attached and not oxidised. Test the internal resistance of the differential lock solenoid (for details, see section 40). With the starter key in the “O” (OFF) position, connect a test meter to pin 2 of connector “EV DF” and to cab earth, and measure the resistance to verify that there are no short circuits to earth (meter reading: infinity).
Clear all alarms, turn the starter key first to “O” (OFF) and then back to the “I” (ON) position again, and if the alarm is still present, the control unit must be renewed. 20-63 0.012.8732.4 5 4 2 20 JX1 4 5 20 2 JX2 GND4 J2 TKAB2 5 2 F34 7.5A +15 0441.9533 13 GND2 EV DF 1 2 0.012.8672.4 D0017621 4 5 20 5 2