Deutz — 5.1.4 ANALYSIS OF LIFT AND ASM ALARMS

5. ALARMS 5.1 LIFT AND ASM CONTROL UNIT ALARMS Extended alarm: 62 NoRightDraftSens. Standard alarm: 31 DESCRIPTION The control unit detects that the right hand draft sensor is disconnected. CHECK Check that the contacts on connector “RIGHT DRAFT” and on those of the lift control unit, “JX1” and “JX2”, are firmly attached and not oxidised.

With the starter key in the “I” (ON) position, check that the power input to the draft sensor is correct (8 V approx meas- ured between pin 3 (positive) and pin 1 (negative) of connector “RIGHT DRAFT”) With the starter key in the “O” (OFF) position, connect a test meter to pin 2 of connector “RIGHT DRAFT” and pin 17 of connector “JX2”, and measure the resistance to verify the continuity of the circuit (meter reading: 0 Ohm). Verify the correct operation of the sensor (for technical details, see section 40). Clear all alarms, turn the starter key first to “O” (OFF) and then back to the “I” (ON) position again, and if the alarm is still present, the control unit must be renewed..