Deutz — 5.1.4 ANALYSIS OF LIFT AND ASM ALARMS

5. ALARMS 5.1 LIFT AND ASM CONTROL UNIT ALARMS Extended alarm: 72 SetPoint Potent. Standard alarm: 23 DESCRIPTION The control unit detects that the depth potentiometer is disconnected or short-circuiting. NOTA In the event of the "DownSpeedPotent.", "SetPoint Potent.", “CtrlMode Potent.”, “MaxHeightPotent.” and “Hitch- ControlLev." alarms being displayed simultaneously, connect a test meter to pin 11 (positive) and pin 9 (negative) of connector “X14” on the control unit, and check that the voltage is between 7.5 and 8.5 V.

If the value is within range, check the continuity of the wiring and make certain there are no short circuits to earth or to a positive leg of the power harness between the lift control unit and the lift control console. CHECK Check that the contacts on connector “X14” of the lift control console and on connectors “JX1” and “JX2” of the lift con- trol unit are all firmly attached and not oxidised.

With the starter key in the “I” (ON) position, check that the power input to the lift control panel is correct (8 V approx measured between pin 3 (positive) and pin 1 (negative) of connector “EHR”) With the starter key in the “O” (OFF) position, connect a test meter to pin 6 of connector “X14” and to cab earth, and measure the resistance to ensure there are no short circuits to earth (meter reading: infinity). With the starter key in the “I” (ON) position, connect a test meter to pin 6 of connector “X14” and to chassis earth, and check to ensure there are no short circuits to positive (meter reading: 0V).

With the starter key in the “O” (OFF) position, connect a test meter to pin 7 and pin 18 of connector “JX1”, and measure the resistance: the reading should be between about 220 Ohm and about 1150 Ohm. Clear all alarms, turn the starter key first to “O” (OFF) and then back to the “I” (ON) position again, and if the alarm is still present, the control unit must be renewed. 5:51/:& 9 4 1& // /5 >/ !0 +", 51:=400 20-71 4 /5 // 1& 9 4 / 11 0 = 9 ? 1 / 0