5. ALARMS 5.2 LIST OF TRANSMISSION CONTROL UNIT ALARMS ALARM N° 50 DESCRIPTION The control unit detects that the rpm sensor nHk is disconnected or short-circuiting to positive ECU RESPONSE The control unit limits operation to “LIMP-HOME” mode, and at the first attempt to shuttle in either direction, the trans- mission will revert to neutral, emitting a continuous beep. CHECK Check that the contacts on connector “NHK” and on connector “ECU PS” of the transmission control unit are firmly at- tached and not oxidised.
With the starter key in the “I” (ON) position, check that the power input to the transmission output speed sensor is cor- rect (12V measured between pin 3 (positive) and pin 1 (negative) of connector “NHK”). With the starter key in the “I” (ON) position and connector “ECU PS” unplugged, connect a test meter to pin 1 of con- nector “NHK” and to transmission earth, and check that there is no voltage registering (meter reading 0V). With the starter key in the “O” (OFF) position, connect a test meter to pin 2 of connector “NHK” and to pin 62 of con- nector “ECU PS”, and measure the resistance to verify the continuity of the circuit (meter reading: 0 Ohm).
Verify the correct operation of the sensor (for technical details, see section 40). Clear all alarms, turn the starter key first to “O” (OFF) and then back to the “I” (ON) position again, and if the alarm is still present, the control unit must be renewed. 20-105 0.012.8732.4 1 2 3 21 23 45 62 68 2145 23 68 1 2 62 3 ECU PS GND4 J2 TKAB2 3 6 1 F35 F27 F16 7.5A 7.5A 3A +15 +30 +15 0441.9533 1 2 6 3 2 1 NHK 0.012.8672.4 D0017341 21 45 23 68 1 2 62 GND4 3 6 1 1 2 6 3 2