Deutz — 5.2.4 ANALYSIS OF ALARMS

5. ALARMS 5.2 LIST OF TRANSMISSION CONTROL UNIT ALARMS ALARM N° 77 DESCRIPTION The control unit detects that the proportional solenoid valve operating the main clutch is short-circuiting to earth ECU RESPONSE The control unit limits operation to “TC-SHUTDOWN” mode and the transmission reverts to neutral, emitting a continuous beep. CHECK Check that the contacts on connector “EV PROP” and connector “ECU PS” of the transmission control unit are firmly attached and not oxidised. Test the resistance of the solenoid (for details, see section 40).

With the starter key in the “O” (OFF) position and connector “ECU PS” unplugged, connect a test meter to pin 2 of con- nector “EV PROP” and to transmission earth, and measure the resistance to verify whether or not there are short circuits to earth (meter reading: infinity). With the starter key in the “I” (ON) position, check that the power input to the proportional solenoid valve is correct (12V measured between pin 2 (positive) of connector “EV PROP” and transmission earth) Clear all alarms, turn the starter key first to “O” (OFF) and then back to the “I” (ON) position again, and if the alarm is still present, the control unit must be renewed.

0.012.8732.4 1 2 8 11 13 21 23 45 32 55 56 57 68 ECU PS TKAB1 F35 EV GROUP EV PROP Prop 0441.9533 0.012.8672.4 D0017611 20-121 21 45 23 68 1 2 11 8 57 32 13 55 56 GND4 J2 3 5 1 6 16 21 1 7 22 E F C D 4 2 3 2 1 U