Deutz — 5.2.4 ANALYSIS OF ALARMS

5. ALARMS 5.2 LIST OF TRANSMISSION CONTROL UNIT ALARMS ALARM N° 80 DESCRIPTION The control unit detects that the forward drive solenoid valve Y3 is short-circuiting to earth ECU RESPONSE The control unit limits operation to “TC-SHUTDOWN” mode and the transmission reverts to neutral, emitting a continuous beep. CHECK Check that the contacts on connector “EV GROUP” and connector “ECU PS” of the transmission control unit are firmly attached and not oxidised. With the starter key in the “O” (OFF) position, connect a test meter to pin A and pin D of connector “EV GROUP” on the transmission, and measure the resistance of the solenoid (for details, see section 40).

With the starter key in the “O” (OFF) position and connector “ECU PS” unplugged, connect a test meter to pin D of connector “EV GROUP” and to the transmission earth, and measure the resistance to check for short circuits to earth (meter reading: infinity). With the starter key in the “O” (OFF) position and connector “ECU PS” unplugged, connect a test meter to pin A of connector “EV GROUP” and to the transmission earth, and measure the resistance to check for short circuits to earth (meter reading: infinity).

With the starter key in the “O” (OFF) position and connector “ECU PS” unplugged, connect a test meter to pin 2 and pin 3 of connector “EV GROUP”, and measure the resistance to verify that the wires are not short-circuiting one to another (meter reading: infinity). Clear all alarms, turn the starter key first to “O” (OFF) and then back to the “I” (ON) position again, and if the alarm is still present, the control unit must be renewed. 0.012.8732.4 1 2 8 11 13 21 23 45 32 55 56 57 68 ECU PS TKAB1 F35 EV GROUP EV PROP 0441.9533 0.012.8672.4 Prop D0017611 20-123 21 45 23 68 1 2 11 8 57 32 13 55 56 GND4 J2 3 5 1 6 16 21 1 7 22 E F C D 4 2 3 2 1 U