Deutz — 5.2.4 ANALYSIS OF ALARMS

5. ALARMS 5.2 LIST OF TRANSMISSION CONTROL UNIT ALARMS ALARM N° 95 DESCRIPTION The control unit detects that the forward drive solenoid valve Y3 is short-circuiting to positive. ECU RESPONSE The control unit limits operation to “TC-SHUTDOWN” mode and the transmission reverts to neutral, emitting a continuous beep. NOTE This alarm could be displayed as a result of alarm 89 being activated. CHECK With the starter key in the “I” (ON) position and connector “ECU PS” unplugged, connect a test meter to pin A of con- nector “EV GROUP” and the transmission earth and check that there is no voltage (meter reading: 0V).

With the starter key in the “I” (ON) position and connector “ECU PS” unplugged, connect a test meter to pin D of con- nector “EV GROUP” and the transmission earth and check that there is no voltage (meter reading: 0V). Clear all alarms, turn the starter key first to “O” (OFF) and then back to the “I” (ON) position again, and if the alarm is still present, the control unit must be renewed. 0.012.8732.4 1 2 8 11 13 21 23 45 32 55 56 57 68 ECU PS TKAB1 F35 EV GROUP EV PROP Prop 0441.9533 0.012.8672.4 D0017611 20-133 21 45 23 68 1 2 11 8 57 32 13 55 56 GND4 J2 3 5 1 6 16 21 1 7 22 E F C D 4 2 3 2 1 U