Deutz — 5.3.2 ANALYSIS OF ALARMS

5. ALARMS 5.3 LIST OF ALARMS DISPLAYED BY SERDIA SERDIA ALARM N° 35 DESCRIPTION The engine control unit detects that the engine is or has been running overspeed (above 3300 rpm). NOTE This alarm is activated generally when, with the tractor on a down gradient, the engine is made to operate as a brake and forced to run at higher speed. Generally, this alarm will disappear automatically when the tractor returns to level ground. In this case, there is no need to make any checks. CHECK Check with the Serdia program that the parameter “21 Speed over” is correct (normal value: 3300 rpm) .

Check that the engine speed pickup sensor functions correctly and does not give a false reading; use an external sen- sor and compare the reading obtained with the value received from the pickup by the engine control unit. Check that the injection pumps control rod slides freely. Check that the internal resistance values for the actuator are correct (for details see section 40). Check that the parameter “1 TeethPickUp1” is correct (normal value=44). 20-149