Deutz — 5.3.2 ANALYSIS OF ALARMS

5. ALARMS 5.3 LIST OF ALARMS DISPLAYED BY SERDIA SERDIA ALARM N° 41 DESCRIPTION The engine control unit has detected a coolant temperature higher than the alarm threshold. CHECK Check that the coolant level is within normal limits . Check with the Serdia program that the parameter “514 CoolantTempEcy” (normal value: 130 °C) is correct. Verify the correct operation of the sensor (for technical details, see section 40). With the starter key in the “O” (OFF) position, connect a test meter to pin 1 of connector “B43” and to engine earth, and measure the resistance to verify that there are no short circuits to earth (meter reading: infinity).

20-151 0.012.8732.4 10 9 8 2 14 1 10 9 8 MX1 1 2 14 MX2 GND4 MS1 J1 2 0.013.5915.4 4 22 7 F30 7.5A +15 0441.9533 9 8 B43 1 2 0421.3172 t° 8 D0022721 10 9 8 1 2 14