Deutz — 5.4.4 ANALYSIS OF ALARMS

5. ALARMS 5.4 LIST OF FRONT AXLE SUSPENSION CONTROL VALVE ALARMS 5.4.4 ANALYSIS OF ALARMS ALARM N° 11 As. SV Fa. or NC DESCRIPTION The control unit detects that the front axle 'up' valve solenoid is not connected. CHECK Test the internal resistance of the solenoid (the resistance value must be other than infinity) . Check that the contacts on connector “JX3” of the control unit and connector “H” of the front axle up valve solenoid are firmly attached and not oxidised. Check for electrical continuity between pin 2 of connector “H” and pin 1 of connector “JX3”.

With the starter key in the “O” (OFF) position, connect a test meter to pin 1 of connector “H” and to chassis earth, and measure the resistance to verify the continuity of the circuit (meter reading: 0 Ohm). If the fault persists, renew the control unit. 20-164 0443.7850 20 5 4 1 JX3 1 20 4 5 FE2 0.012.8732.4 FE1 8 GND4 3 J2 1 7 2 1 H 0443.7849 7 F17 7.5A +15 0441.9533 D0017210 1 20 4 8 3