EDS (Electronic Diagnosis System) POWER-SHUTTLE DIAGNOSISPROGRAMM DEST 45 20-211 Remarks • Self preservation • Upon neutral shifting permanent beep • EC also defective with term30 • LU VPS can also lead to sequence errors F-/R-/prop.-SV) • Possibly sequence error resulting from counter supply (K+) at F/R valve upon power on • Possibly sequence error from LU proportional valve • Possibly sequence error from:
Safety processor not programmed • Self preservation • Upon neutral shifting permanent beep • EC also defective with term30 • LU VPS2 can only be detected via sequence errors • Possibly sequence error resulting from counter supply (K+) at GV/HV/ MVKl upon power on • Possibly sequence error from: Safety processor not programmed •HK plausibility only if configured •Self preservation Nisa-HK-Nhk •Plausibility circuit: •For T72 creep speed lever Position”N” is possible!
possible remedy Check cabling (KM, K+) Check voltage at VPS 1 Check voltage at term30 Check cabling delle valvole F/R (K+) Check cabling (KM, K+) Check voltage at VPS 2 Check voltage at term30 Check cabling di GV/HV/MVKI (K+) Engage/disengage creep speed lever Check cabling at proportional valve (K+) Check proportional valve Check HK Check speed sensory system Nlsa, Nhk Check hydraulic system Ignition off/on Check vehicle electrical system Check cabling System reaction Neutral shifting Operation mode SHUT DOWN VEHICLE Neutral shifting Operation mode PERMANENT NEUTRAL Neutral shifting Operation mode SHUT DOWN VEHICLE Neutral shifting Operation mode SHUT DOWN VEHICLE Error location/error cause VPS1 plausibility (KM, K+) VPS2 plausibility (KM, K+) HK plausibility circuit Vehicle electrical system overvoltage Code 89 90 91 92