Deutz — 4.1 PROGRAM DESCRIPTION

EDS (Electronic Diagnosis System) DIAGNOSIS OF THE INFOCENTER 4.1.2 F1 – CONSTANTS CHANGE By pressing the key F1 an additional window headlined “display and program constants” appears: Fig. 53 - Display and program constants It is possible to compare the stored constants in the Infocenter with the help of the constant list (see item 3, resp. vehicle workshop manual). Procedure for changing constant values: Select the desired constant value by means of the cursor keys (the corresponding line is highlighted) - Press the ENTER key. By doing so, another window appears in which the new value can be entered. - Press the ENTER key again to confirm the change and return to the constant values menu.

When the proper values are assigned to all constants, the main menu is called again by selecting the bottom line “End constant values menu” (and pressing ENTER). CAUTION! The realized changes are only saved after terminating the diagnosis program and subsequently switching the ig- nition off and on again. 20-223