Deutz — 1.1 LIFT

ALL ROUND TESTER FOR LIFT AND ASM CONTROL UNIT 1. MONITOR Slipage: Wheelslip status Ref: setting selected with the wheelslip potentiometer (settings: ON = active - OFF = inactive) The value displayed after the setting indicates actual wheelslip (0-100). With the tractor stationary this must be 0%. Radar: Ground speed detected by the radar. Values displayed: : radar not active : speed (0-50 km/h) Wheel: Wheel speed detected by sensor Values displayed: : speed (0-50 km/h) Mode -> : Lift control mode selected by way of “MIX” potentiometer. Values displayed: DRAFT: lift in draft control mode POS: lift in position control mode MIX: draft and position control intermixed. EV up:

Status of linkage Up solenoid valve EV dw: Status of linkage Down solenoid valve NOTE “Up SV” and “Dw SV" must not register status at the same time. Pwm: Control signal sent to “Up” or “Down” solenoid valve currently active. Two columns are displayed: 0-1000 value of control signal 0-5000 mA current Press to quit this menu. E 20-239 L I F T = = = = = = = = = = = = = = = = S t a t u s . . . X X X X X X M i n P o s i t . M a x X % X . X % X % L t D r a f t R t X . X X X . X % X . X X S l i p a g e R e f : X X X X X X % R a d a r K m h X . X W h e e l K m h X . X M o d e -> X X X X X E V u p X X X E V d w X X X P w m X X X X X X m A [ E ] E x i t - - - - X X . X X X . X