SERDIA MEASURED VALUES 3.1.2 GRAPHICS If up to any 5 measured values have been selected, the "Graphic display" window can be opened by clicking on "Graph- ics". The measured values are displayed within the display range (minimum to maximum). The scaling divisions for the axes are set in the column called "Delta". It is possible to let the program carry out automatic scaling by activating the control field called "Auto". Because the program does this scaling based on the minimum and maximum values of the respective measured values, it is not possible to have automatic scaling for time-constant measured values.
A maximum of two axes, one on the left and one on the right side of the graph will be drawn. A measured value can be as- signed to a left or right axis in the columns marked L (left) and R (right). EXPLANATION OF THE FUNCTION BUTTONS: Start : The data recording operation is started using this function button. Update : This function button is used to update the information displayed. This is required if a change has been made to the minimum, maximum or delta values. The update takes account of the new values. Print : Clicking on this button will commence output to a printer.
The printer selection screen is displayed first, then the user has the option of entering any comments before the graph is finally printed out. Save : The information displayed can be saved to a file in two different ways: 1) As an ASCII file (*.agr) for further processing, e.g. in Excel. 2) As a binary file (*.egr) for display of measurement graphics in offline mode, see 1.9 Offline mode. Apri: Load : The graphics information stored in a file is loaded and displayed. 20-275