Deutz — 3.5 CAN STATUS

SERDIA MEASURED VALUES 3.3 DATA LOGGER (ONLY EMS2) The screen for this menu item can only be selected if an EMS2 has been selected as the control unit. 3.4 INPUT/OUTPUT ASSIGNMENT The inputs and outputs can be configured. This menu item displays the current input and output assignment. Limitation : EMR1 and EMS2 control units only. 3.5 CAN STATUS This window displays the CAN bus activities of the EMR1 or EMR2. EMR1 EMR2 Sent : Contains the information Can:TxCounter (0 to 65535, word). The value is increased with every CAN send mes- sage and displays the sending activity of the EMR1. Received : Contains the information Can:RxIrCounter (0 to 65535, word).

The value is increased with every CAN send message and displays the sending activity of the EMR1. Bus off : Counter indicating how often the EMR1 has disconnected from the CAN bus because of continuous errors (CanBusOffCounter 0 to 255, bytes). Status : CanOnline indicates whether the EMR1 is active on the CAN bus. A value 1, for online and a value 0, for offline, is sent via the ISO 9141 interface. The SERDIA program displays the text "online" (for value 1) or "offline" (for value 0). 20-280