Deutz — 8.1 SERDIA GENERAL

SERDIA WHAT TO DO IF...? 8. WHAT TO DO IF...? 8.1 SERDIA GENERAL 8.1.1 ERROR WHILESETTING UP COMMUNICATIONS If communications cannot be set up although the interface and control unit have been connected, an error message is dis- played: Possible reasons for the error message: No supply voltage to the control unit or interface. Voltage supply was cut when the engine was switched off. Incorrect assignment of serial interface on PC (see 9.1.2). Wrong pole connection on voltage supply from engine to interface. Not all of the 4 wires (+, -, k, l) are connected. Wrong control unit, or control unit faulty. Remedy, quick checks: Yellow interface LED should light up when SERDIA is started.

Measure the diagnostic connector supply voltage (the interface requires 8 - 28 V DC). In Windows, check the assignment of the serial interface (usually COM1). Connect another control unit. Further information on operating voltages for control units, interface and PC: EMR control units require an operating voltage from 10 V to 30 V (typically 12-24 V). Power consumption: 5 A at 12 V, 7 A at 24 V The MVS control unit takes a voltage of 24 V only. The interface is supplied by the engine and takes a voltage from 12 V to 24 V. The control units and interface are protected against wrong pole connection and overvoltage.

However, an accidental incorrect connection, to a 230 V source for example, can still cause damage. Using an interface with an integrated optical link, the PC (Notebook, and printer) can be connected to the vehicle battery and ground with no risk for the control unit and interface, and no risk of loss of data. 20-303