Doosan DX225LC-3 — Breaker Operating Precautions

Breaker Operating Precautions NOTE: Hydraulic pressure and flow settings may need to be changed. Refer to the Maintenance Section of this manual for further information. 1. Make sure to read and understand the breaker operator's manual. 2. Inspect all mechanical and hydraulic connections. 4. Do not drop breaker from extreme heights. 3. Do not use the breaker as a hammer. See Figure 116. This can damage breaker or the excavator. Figure 116 FG018435 5. Do not operate the breaker with the boom or arm cylinders fully extended (bottomed out). See Figure 117. Leave over 100 mm (4 in) of clearance between rod end of cylinder and cylinder head.

This will help prevent damage to cylinders during breaker operation. Figure 117 6. Do not use the breaker if the hydraulic hoses vibrate excessively. See Figure 118. Check the breaker's hydraulic accumulator (1) for damage and repair as required. If excavator is operated under this condition, structural and hydraulic components can be damaged. 1 FG018437 Figure 118 DX225LC-3 Operation 3-56 FG018436