Troubleshooting 6-9 DX225LC-3 AIR COMPRESSOR (OPTIONAL) Problem Cause Correction Compressor does not run. Power supply failure. Check power connection. Blown fuse. Check the power supply line polarity (+, -), and replace the fuse. Motor overheat. Let the motor be cooled down for about 10 minutes, and restart it. Motor operated for more than 30 minutes continuously. Let the motor be cooled down for about 10 minutes, and restart it. Purge valve failure. Check/replace the purge valve. Motor hums or runs slowly. Low voltage. Check the input voltage. (24V min.) Worn brush. Replace the brush. Tank pressure is lowered when the compressor is turned off - pressure gauge. Loose joint.
Check pipeline joints. Excessive moisture in the air ejected from the air gun. Drain valve open/leak. Check the drain valve. Check valve leak. Overhaul or replace the check valve. Warning! Never remove check valve when the tank is pressurized. Too much water in the tank. Drain the tank. Warning! Drain the tank when the pressure in the tank is less than 1 bar. Compressor keeps running. Pressure switch failure. Replace the pressure switch. Excessive air use. Restart the compressor after checking that air tank pressure is charged up to 8 bar. Compressor vibrates. Loose mounting bolt(s). Tighten the mounting bolt(s). Mounting rubber pad is worn or missing. Replace the mounting rubber pad.
Air pressure is lower than normal. Drain valve is open. Close the drain valve. Clogged air suction filter. Clean/replace suction air filter. Leak at joint. Check/tighten the joints.