1. Starter Switch O I A three-position starter switch is used to start or stop engine for equipment operation. O. Turning switch to this position turns engine "OFF" with its electrical system. In this position, engine is "OFF" but interior cabin light and fuel tank transfer pump (if equipped) are functional. I. Turning switch to this position turns engine electrical system "ON". When the switch is first turned "ON", six indicator/warning symbols across top of the display monitor, will turn "ON" for approximately two seconds. The battery warning symbol and engine oil pressure warning symbol should remain "ON" after the other four have turned "OFF". FG018093 Figure 4 NOTE:
Preheat Indicator Symbol - The operation of the preheat cycle depends on coolant temperature. When the engine coolant is cold enough, the preheat indicator symbol will remain "ON" until engine preheat cycle is completed. The preheat cycle takes about twenty seconds to complete, and the indicator symbol will turn "OFF". When the symbol turns "OFF", engage the starter. . Moving switch to this position will crank engine. When engine starts, release key and allow it to return to "I" (ON) position. Do not operate the starter switch for more than fifteen seconds at a time. This will help prevent damage to starter. WARNING AVOID DEATH OR SERIOUS INJURY DO NOT USE STARTING FLUIDS.
The preheat system could cause the starting fluid to explode. 2. Heater and Air Conditioner Control Panel This panel is used to control air conditioner and heater in operator's cabin. Refer to “Heater and Air Conditioner Control Panel” on page 2-74, for more information. A/C AUTO TEMP AUTO A/C OFF MODE SEL FG000029 Figure 5 DX225LC-3 Operating Controls 2-8 OUTSIDE O MAX