Komatsu — CLEAN INSIDE OF COOLING SYSTEM

. MAINTENANCE SERVICE PROCEDURE MAINTENANCE SERVICE PROCEDURE Run at low idling for 10 minutes to raise the water temperature to above 90 ° C (194 ° F). 8. Stop the engine, open drain valve (a), drain the water, then then run for another 5 4 - 29 4. Loosen sub-ta nk cap (3) a little to release th e residu al pressure and then remo 5. Open drain val ve (4) in the oil co oler and d rain the water. After draining t water. Fill the radiato start the engin he water, close drain valve (4) and fill with city r, sub-tank and reservoir tank with water, then e and run at low idling. close the valve 9.

Replace the co rrosion resistor, th en turn v alve (2) to ope For replacing c orrosion resistor, see "REPLACE C ORROSIO N RESISTOR CARTRID 10. Add coolant m ixed with antifreez e until it o verflows from t he w ater filler. Decide the pro portions of antifree ze and wa ter according t o the table for the mixing rate 11. To remove the air contained in t he coolan t, run th e engine a t low idle for 5 minutes cap OFF.) minutes at hig h idle. (When doin g this, lea ve the c oolant filler 12. Stop the engin e. About 3 minute s later, su pply the coolan t up to the coolant filler, then 13.

Drain the wate r from reservoir ta nk (5), flu sh the in side o f the reservoir tank, then add water to between the FULL and LOW marks. reservoir tank, then add water to between t he FUL L and L OW