Komatsu — 3.4.5 TABLE OF AVAILABLE INSTRUCTION MESSAGES

3.4 VEHICLE HEALTH MONITORING SYSTEM VHMS – HEALTH MONITOR OPERATION 3.4.5 TABLE OF AVAILABLE INSTRUCTION MESSAGES NOTICE TOP Messages and applying Instruction Messages are always displayed together. 120 Message No. Instruction Message 0 1 Engine stopped because of main Shut-Off (gate) valve. - Open the Shut-Off (gate) valve. - If failure exist further, inform service. 2 Inform service. 3 Stop the engine. - Inform service. 4 Start blocked because of main Shut-Off (gate) valve. - Open the Shut-Off (gate) valve. - If failure exist further, inform service. 5 Start blocked. - Inform service. 6 The fire suppression system has been actuated. - Inform the fire brigade.

- Evacuate endangered persons. - Fight the fire. - Inform service. 7 Bucket motion switched off. - Inform service. 8 Circuit breaker F13 switch on. - If failure exist further, inform service. 9 Ladder end switch or seat contact open. - If failure exist further, inform service. 10 Emergency shut-down switch was actuated. - Unlock before restarting. - If failure exist further, inform service. 11 Engine switched off by Maintenance safety switch in the engine room. - Unlock before restarting. - If failure exist further, inform service. 12 13 14 Enable switch for refilling arm active. - If failure exist further, inform service. 15 Load of the batteries too high. - Inform service.

16 Batteries are not being charged. - Inform service. 17*) Inform service till end of shift and then press cancel button. NOTICE The message number G00169 indicates two trouble conditions, either return oil filter restric- tion or restriction of the return oil strainer in the return oil collector pipe. To find out the unit which caused the fault message, check the LED number H74 on the Programmable Logic Controller (E6) located on the main switch board (X2) in the cab base, see page 143. If the LED H74 is OFF, the return oil filters in the oil tank are restricted and need to be replaced.

If the LED H74 is ON, the return oil strainer in the return oil collector pipe is restricted and needs to be replaced. Refer to page 391 in the maintenance section 4 for servicing instruc- tions.