Komatsu — 3.15 STOPPING THE ENGINE

OPERATION 3.15 STOPPING THE ENGINE Never stop the engine from full load except in case of emer- gency. Before shutting down run the engine at idling speed for approximately 5 minutes. This cooling down period prevents heat accumulation and thermal stress, especially in the tur- bochargers. For EMERGENCY SHUTDOWN of the Engine, use STRIKE BUTTON (8). Additional emergency shut-down switches are located on the power house. For more information See "POWER HOUSE" on page 126. Stopping procedure, illustration Z25449 1. Park the Shovel at a safe place on level and solid ground. For more information See "PARKING THE SHOVEL" on page 189. 2.

Deposit the working attachment onto the ground, proceed as follows: A - Backhoe Attachment Lower the backhoe attachment fully extended onto the ground as shown on the oil level plate at the main hydrau- lic oil reservoir. B - Bottom Dump Bucket Attachment Lower the bottom dump bucket attachment onto the ground with the stick fully retracted and with the bucket resting completely flat on the ground. This position is shown on the oil level plate at the main hydraulic oil res- ervoir. The positions A or B are necessary to prevent unintentional movement of the working attachment when the pressure in the hydraulic system is relieved, and for correct checking of the hydraulic oil level. 3.

Move all controls into neutral position. 4. Set toggle switch (4) to low idle speed position. Let the engine idle for about five minutes without load. 5. Turn switch (7) clockwise to stop position. When the engine has come to standstill, relieve the pressure in the hydraulic system. 191 CAUTION CAUTION CAUTION CAUTION