OPERATION 3.19 CENTRAL REFILLING SYSTEM Legend for illustration Z 21623 219 12 Adapter for evacuation and filling of the main hydraulic oil reservoir. After the oil is completely evacuated, drain the oil from suction oil reservoir, collector pipe and back- pressure valve pipe. Refer to maintenance section, item hydraulic oil change for draining procedure. Open the shut-off valve between main oil reservoir and suction oil reservoir. Fill the hydraulic reservoir and observe indicator lamp (13). 13 Indicator lamp lights up when the hydraulic oil level in the reservoir is correct. Recheck hydraulic oil level at the sight gauge before operating the machine.
14 Adapter for filling the grease barrel of the Central Lubri- cation System (CLS). Before filling the grease barrel make sure the grease filter in the filling line is not obstructed. 15 Indicator light, grease barrel of Central lubrication Sys- tem FULL. 16 Adapter for filling the grease barrel of the Swing circle pinion Lubrication System (SLS). Before filling the grease barrel make sure the grease filter in the filling line is not obstructed. 17 Indicator light, grease barrel of Swing circle pinion Lubri- cation System FULL.