OPERATION 3.3 OPERATOR’S CAB - CONTROLS Switch Board (continued) Legend for illustration Z25446 (10) Switch for main working lights (11) Toggle switch, swing parking brake 0 - Parking brake released - UP 1 - Parking brake applied - DOWN. The parking brake should only be applied with superstructure at complete standstill, except in case of emergency. Refer to page 176 for more information. (12) Enable switch for hydraulic service arm operation. Set this switch to ON position ”1” before lowering the ser- vice arm. With this switch in ON position, the pilot con- trol system is made inoperative and the hydraulic swing brake is applied.
After completion of replenishment pro- cedure, swing back the service arm to its home position and set switch (12) to OFF position ”0”. (13) Switch, manual actuation of central lubrication system (14) Switch, windshield washer (15) Switch, mirror heating (16) Switch, cab ventilation blower. Blower runs with low speed, even with switch in -0- position. (Cab pressuriz- ing prevents ingress of dust). (17) Switch, manual actuation of swing ring gear pinion lubri- cation system (18) Switch for upper and lower windshield wiper 0 - Off 1 - Interval stage 2 - Slow stage 3 - Fast stage (19) Switch for Truck counter number 2 (TR2). For counting loaded trucks rotate this switch.
The total number of trucks loaded is shown on the VHMS monitor field TR2, refer to page 96 for more information. The push button for Truck counter number 1 (TR1) is located on the RH control lever. (20) Swing speed switch. 0 - Normal swing speed. 1 - Increased swing speed. It is recommended to use the higher swing speed for slewing angles greater than 90°. 91 CAUTION CAUTION