Komatsu — SLOW BLOW FUSE

. OPERATION EXPLANATION OF COMPONENTS CIRCUIT BREAKER NOTICE When resetting the circuit breaker, always turn the starting switch OFF first. Do not keep the circuit breaker reset button pressed. so SLOW BLOW FUSE If the power does not come on when the starting switch is turned ON, the slow-blow fuse may be blown, so check and replace it. The slow blow fuse is beside the engine on the right side of the machine. SLOW BLOW FUSE (1) 120A: Alternator power supply (2) 80A: Main power 3 - 52 If the electric power d oes not come on when the st turned ON, the circu check. The circuit breaker is at the side of the engine on t he right s the machine.

REMARK The circuit breake r is a circuit protection device installed to circuits where a large capacity electric current is flowing. In the sam is an abnormal flo parts. It can simply e way as a normal fuse, it pro tects the electrical equipment and wiri ng from damage if there w of electricity. However, after the problem point recovers, there is no need to replace any be reset. When resetting the electric circuit after it has bee n cut off, wait for 5-10 minutes after the circuit was cut off, then press the reset but button may be hea There is no differe condition when it h If the circuit reset o inspect the electric ton.

When resetting the electri c circuit after it has been cut off, the ope rating effort of the reset vier than when operating it in normal c onditions. nce in the height of the reset b utton between the condition when that t he circuit is cut off or the as been reset. Check that the circuit ha s been reset by the effort need ed to operate the button. peration is carried out but the operatin g effort for the reset button is heavy, it is necessary to circuit. If the starting moto r does not start even when the starting switch is turned to the START position, circuit breakers (1), (2), or (3) have probably cut off the circuit, s o check and reset circuit breakers (1), (2), and (3).

If the electrical equ ipment does not work even w hen the fu se has been replaced, circuit b reaker (1) has probably cut off the circuit, s o check and reset circuit bre aker (1). No. Fuse capacity Name of circuit (1) 30A Battery power source (Starting switch, Hazard) (2) 20A Engine controller 1 power supply (3) 20A Engine controller 2 power supply