Komatsu — STARTING ENGINE

. OPERATION OPERATION OPERATION OPERATION of the 3. When preheating pilot lamp (3) goes out, turn the key in starting switch (1) to the START position. The engine will start. 4. After the engine starts, release the key in starting switch (1). The key will automatically return to the ON position. REMARK Immediately after the engine starts, the turbocharger protect function prevents the engine speed from going above 1000 rpm for a maximum of 20 seconds, even if the accelerator pedal is depressed. If the accelerator pedal is kept depressed, the engine speed will suddenly rise after the turbo protect time. To prevent this, release the accelerator pedal.

The turbocharger rotates at extremely high speed. Immediately after the engine is started, the pressure of the lubricating oil has not risen sufficiently, so if the engine speed is suddenly raised, it may lead to damage or seizure of the turbocharger bearing. The turbo protect function acts to prevent this problem. It uses electronic control to prevent the engine speed from rising above a certain speed for the first few seconds after the engine started. 3 - 91 2. Check i f preheating pilot lam p (3) on t he main m onitor is lighted up. If preheating pilo t lamp (3) is not lighted up, go to Step 3. If preheating until it goes o pilot ut.

lamp (3) is lighted up, leave in this condition The guideline for the preheating time is as foll ows. In cold area s, it varies according t o the temperature perature coolant when the engin e is started. Cooling water temperature Pre-heating tim above -5 to -15°C (5 to 23°F) 20 - 30 second -15 to -25°C (5 to -13°F) 30 - 45 second below -25°C (-13°F) 45 second