Komatsu — WHEN REQUIRED

. MAINTENANCE MAINTENANCE PROCEDURE CHECK AND MAINTENANCE AIR CONDITIONER Check Level of Refrigerant (gas) WARNING glass (2) (inspection window) of the receiver (1) when the cooler is running at high speed. (A) No bubbles in refrigerant flow: Suitable (B) Some bubbles in flow (bubbles pass continuously): Inspection and Maintenance Items 4 - 39 If the refriger ant used in the air c onditioner ge ts into your eyes o r on your hands, it may cause loss of s ight or frostbite. Do not touch the ref rigerant. Never loo sen any part o f the refrigerant ci rcuit. as is leaking. Do not bring any flame close to any point whe re the refrigerant g as is leaking.

If the level of the refrigerant (gas) is low, the cooling effec t will be reduced. R un the engine at high idle, a nd check the flo w of the refrigerant gas (R134a) in th e refrigerant circuit through t he sight Lack of refr (C) Colorles s, transparent: N o refrigerant REMARK When there are bubbles, the refrigerant g as level is low, so contact your Koma tsu distributors t o have refri gerant added. If the air conditioner is run with the r efrigerant gas level low, it will cause damage to the compressor. Inspection During Off Season Even during the off-season, operate the a ir conditioner for 3 to 5 minutes once a month to ma intain the oil film at al parts of the compressor.

Check, maintenance items Guidelin Content of check, maintenance e for maintenance interval Refrigerant (gas) Charge amount Twice a ye ar (spring, autumn) Air conditioner condenser Clogged fins Every 500 h ours Compressor Operating condition Every 4000 hours V-belt Damage, tension Every 250 hours Blower motor, fan Operating condition When requi (does it make abnormal noise?) red Control mechanism Operating condition (does it function normally?) When requi red Piping mounts Mounting condition, looseness at tightening or When requi connecting portions, leakage of gas, damage red