. MAINTENANCE MAINTENANCE PROCEDURE CHANGE OIL IN FINAL DRIVE CASE WARNING 4 - 73 EVERY 2000 HOURS MAINTEN Maintenance for every 50, 250, 500 a nd 1000 hours se rvice should be c arried out at the sa me time. The parts and oil are at high temperature immediately after t he engine is stopped, an d may cause se rious burns. Wait fo r the temperature to g o down before starting the operation. If there is still pr essure remaining inside the case, the oil or plug may fly Loosen the plug slowly to release the pr Refill capacity (each): 8.5 liters (2.2 Prepare a han 1. Set the TOP mark at the top, with the TOP mark an d plu g (P) perpendicula r to the ground surfac e. atch the oil.
handle and drain the oil. 2. Set a contain er under plug (P) to c atch the oil. 3. Remove plug s (P) and (F) with the handle and drain the oil. REMARK Check the O-ring s in the plugs for da mage. If necessar with new ones. 4. Tighten plug (P). h the hole of plug (F). 5. Add oil throug h the hole of plug (F 6. When oil begi ns to overflow from t he plug (F) hole, i nstall plug (F). rque of plugs (P) and (F): (7 ± 1 kgm, 50.6 ± 7.2 lbft) Tightening to rque of plugs (P) and 68.6 ± 9.8 Nm (7 ± 1 kgm, 50.6 ± REMARK There are two plu gs (F). Add oil throug h the one easier to fill oi l and through which no internal gears are to be seen.