Appendix A • Parameter Listings Idle Shutdown Calibration NOTE: i The Park Brake/ISD (Idle Shut-Down) function must be a switch input to the ECM to allow idle shutdown to be enabled. This is available through factory programming only. The following table lists all Idle Shutdown Configuration parameters. 170 Detroit Diesel Application User’s Manual Parameter Range Description ENABLED YES, NO, or N/A Allows the idle shutdown timers to be enabled. “N/A” will be displayed if (func- tion #5 PARK BRAKE/ISD) has not been configured for a vehicle switch input. TIME (MIN) 2 TO 100 MINUTES or N/A Determines the idle time before the engine is shutdown.
“N/A” will be dis- played if idle shutdown “ENABLE” = NO or N/A. OVERRIDE YES, NO, or N/A Allows for the disable of the idle shutdown by depressing the throttle and releasing during the Check Engine light flashes prior to engine shutdown. “N/A” will be displayed if idle shutdown “ENABLE” = NO or N/A. ENABLED ON VSG YES, NO, or N/A Allows the idle shutdown function to be enabled when the engine is operating at idle or at a VSG set speed. ‘”N/A” will be displayed if idles shutdown “ENABLE” = NO or N/A. Override Temp Disable LOWER LIMIT Limit -40F° to upper limit This feature does not allow override of idle shutdown if the ambient tempera- ture is between the lower and upper limit.
Lower ambient temperature that will disable idle shutdown. UPPER LIMIT Lower limit to 244F° Upper ambient temperature that will disable idle shutdown.