. MAINTENANCE MAINTENANCE PROCEDURE CHECK AIR CONDITIONER COMPRESSOR BELT TENSION, ADJUST Checking (A): Compressor pulley (B): Crankshaft pulley 2. Loosen bolt (2) and nut (3). 3. Turn nut (4) clockwise and move compressor (5) so that the deflection of the belt is approx. 14-16 mm (at a force of approx. 6 kg). 4. When the position of the compressor is determined, tighten nut (3) and bolt (2) to lock it in position. 4 - 53 when pressed with a fi nger force of approx. 5 8.8N (6 kg) a t mid-point (a) between the cra nkshaft pulley and the compressor Adjustment 1. Remove gua NOTICE Check each pu lley for damage, wear of t he V-groove, a nd wear of the V-belt.
In partic bottom of the V ular, be sure to check that the V-belt is n ot touching the -groove. In case any of t he following occurs, ask th e Komatsu dis tributor in y our territory to repl • The fan belt • A cut or crac • Slipping or c ace the belts with new on es. le allowance for adjustment. ming from the belt. er one hour of operation. has elongated, leaving litt le allowance fo r adjustment. k is found on the belt. reaking sound is heard co ming from the When the new V-belt is set, readjust it aft er one hour of operation.