Komatsu — CHECK AND MAINTENANCE AIR CONDITIONER

. MAINTENANCE MAINTENANCE PROCEDURE Check Level of Refrigerant (gas) WARNING Inspection and Maintenance Items 4 - 43 CHECK AND MAINTENANCE AIR CONDITIONER (If equipped) If t he re frigerant used in the a ir conditioner gets into your eye s or on y our hands, it may c ause loss of sigh t or frostbit e. Do not touch th e refrigerant. Never l oosen any pa rt of t he re frigerant circuit. leaking. Do not bring an y flame close to any point where the r efrigeran t ga s is leaking. If ther e is a lack of r efrigerant (Freon 134a), the cooling er at high speed, there should be no cooling performance will be poor.

When operati ng the cool e sight glas bubble s in th s (inspection window) mounted on the the condenser uni t receiver. Remov e cap ( 1) to see th e sight glass No b ubbles in refrigera nt flow (bubbles pass continuously): Lack Colorless, t ransparent: No refrigera REMAR K When t here ar e bubbles, t he refrigeran t gas leve l is l ow, so contact your K omatsu distributor s to have r efrigerant added. If the air conditioner is run with the refrigerant gas leve will damag e to the compresso Inspection During Off Seas on Even d uring th e off-seaso n, operate th e air conditioner f or 3 to 5 minutes once a month to maint ain the oil f ilm at al parts o f the co mpressor.

Check, maintenance ite ms Content of check, maintenance Guideline for maintenance interval Refrigerant (gas) Charge amount Twice a year (spring, autumn) Air conditioner condenser Clogged fins Every 500 hours Compressor Operating condition Every 4000 hours V-belt Damage, tension Every 250 hours Blower motor, fan Operating condition (does it make abnormal noise?) When required Control mechanism Operating condition (does it function normally?) When required Piping mounts Mounting condition, looseness at tightening or connecting portions, leakage of gas, damage When required