SYSTEM / Control System E Mode Control Purpose: Reduces the engine speed set by the engine control dial according to the pump control pressure and the average pump delivery pressure in order to reduce fuel consumption. Operation: 1. When the required engine speed by the engine control dial is 1850 min -1 or faster and the power mode switch is in the E mode position, and if the pump control pressure and the average pump de- livery pressure are within the following conditions, MC sends the signals equivalent to the target en- gine speed to ECM by using CAN communication. 2. ECM reduces the engine speed from the required engine speed set by the engine control dial. 3.
If the pump control pressure is high and the av- erage pump delivery pressure is low, MC sends the signal equivalent to the target engine speed to ECM by using CAN communication. 4. ECM increases the engine speed by 150 min -1 . Condition: Engine speed is reduced lower than the required engine speed by the engine control dial: Control Pressure of Pump 1 or 2: Low of ei- ther (Reference: 3 MPa (31 kgf/cm 2 , 436 psi) or less) and Average Pump Delivery Pressure: High (Reference: 9.8 MPa (100 kgf/cm 2 , 1425 psi)) Control Pressure of Pump 1 or 2: Low of ei- ther (Reference: 3 MPa (31 kgf/cm 2 , 436 psi) or less) and Average Pump Delivery Pressure: Low (Reference:
Less than 9.8 MPa (100 kgf/cm 2 , 1425 psi)) Control Pressure of Pump 1 or 2: High of ei- ther (Reference: 3 MPa (31 kgf/cm 2 , 436 psi) or more) and Average Pump Delivery Pressure: High (Reference: 9.8 MPa (100 kgf/cm 2 , 1425 psi)) Engine speed is increased to P mode speed Control Pressure of Pump 1 or 2: High of ei- ther (Reference: 3 MPa (31 kgf/cm 2 , 436 psi) or more) and Average Pump Delivery Pressure: Low (Reference: Less than 9.8 MPa (100 kgf/cm 2 , 1425 psi)) Engine Speed Set by E Mode Control Engine Speed Operation Steps 1, 2 Engine speed in- crease by 150 min -1 . Operation Steps 3, 4 P Mode Speed Engine Control Dial Position Slow Idle Fast Idle T2-2-12