SYSTEM / Control System Attachment Operation Speed Increase Control (Only Machine Equipped with Attachment Parts) Purpose: Increases the maximum engine speed to the attachment (hydraulic breaker, secon- dary crusher, primary crusher or vibrating hammer) operating engine speed set by Dr. ZX when the attachment is operated. Operation: 1. When the following conditions exist and the at- tachment is operated, MC sends the signals equivalent to the target engine speed set by Dr. ZX to ECM by using CAN communication. 2. ECM increases engine speed to the attachment operating speed set by Dr. ZX. Conditions: Dr. ZX:
Resets the maximum engine speed to a faster (+) attachment (hydraulic breaker, secon- dary crusher, primary crusher or vibrating ham- mer) operating speed in the service mode. Engine Control Dial: Fast Idle Speed Position Power Mode Switch: HP Mode Auxiliary: Operated Work Mode: Attachment selected by using the at- tachment mode monitor unit is set (+) by Dr. ZX. Engine Speed When all condi- tions exist, the maximum en- gine speed is increased to the speed set by Dr. ZX. Engine Control Dial Position Slow Idle Fast Idle NOTE: When P mode engine speed is preset to a slower speed in Dr. ZX service mode, the maximum engine speed will not be in- creased when operating the attachment. T2-2-22