SYSTEM / Control System Pump 1 Flow Rate Limit Control (Only Machine Equipped with Attachment) IMPORTANT: The maximum pump 1 flow rate limit control solenoid valve has come equipped for ZX160- 3 class and is optional for ZX180- 3 Class. Purpose: Limits pump 1 flow rate in order to make up for pump flow rate for attachment operation when attachment (mainly a vibrating ham- mer) is used and pump 2 flow rate is lack. Operation: 1. When the attachment is used with the travel con- trol lever in neutral, MC receives the signals from pressure sensor (auxiliary) (optional). 2.
In response to attachment control operation, MC drives the maximum pump 1 flow rate limit control solenoid valve and controls pump 1 flow rate. NOTE: The minimum pump swash set-angle on monitor unit for a attachment (hydraulic breaker 1 to 5, secondary crusher 1 to 5, primary crusher 1 to 5 or vibrating hammer 1 to 5) can be set in the service mode of Dr. ZX. T2-2-32