SYSTEM / Control System Pump 1 Flow Rate Control Valve at Travel (ZX160- 3 Class Only) Purpose: Control flow rate of pump 1 when traveling. Operation: 1. When travel is operated during work mode “dig- ging”, MC receives the signal from the pressure sensor (travel) 2. In response to travel control operation, MC drives the maximum pump 1 flow rate limit control sole- noid valve and controls pump 1 flow rate. T2-2-34