SYSTEM / Control System Pump 2 Flow Rate Limit Control (Only Machine Equipped with Attachment) Purpose: Limits maximum pump 2 flow rate when a attachment (mainly a hydraulic breaker) is used. Operation: 1. When attachment is used with the travel control lever in neutral, MC receives the signals from pressure sensor (auxiliary) (optional). 2. In response to attachment control operation, MC drives the maximum pump 2 flow rate limit control solenoid valve and reduces maximum pump flow rate. 3. When the auxiliary flow combining solenoid valve stops, pump 2 flow rate can be adjusted finely by the monitor unit. Q Maximum flow rate is reduced. Flow Rate Normal Pump P-Q Curve NOTE:
In proportion to the attachment control op- eration, maximum pump flow rated is re- duced. The minimum pump swash set-angle on monitor unit for a attachment (hydraulic breaker 1 to 5, secondary crusher 1 to 5, primary crusher 1 to 5 or vibrating hammer 1 to 5) can be set in the service mode of Dr. ZX. P Pressure T2-2-36