hitachi — Valve Control

SYSTEM / Control System Auto-Power Lift Control Purpose: Increases pressure when raising the boom. Operation: 1. MC activates solenoid valve unit (SG) when the signals from pressure sensor (boom raise) and pump 1 delivery pressure sensor meet the following conditions. 2. Solenoid valve unit (SG) delivers pilot pressure to the main relief valve in control valve and increases relief pressure. (Refer to Control Valve/ COMPONENT OPERATION.) Conditions: Boom Raise Pressure Sensor: Outputting signals (The boom must be raised to a certain extent.) (Reference: 1.7 MPa (17 kgf/cm 2 , 247 psi)) Pump 1 Delivery Pressure Sensor: High pressure (Reference:

31.3 MPa (320 kgf/cm 2 , 4550 psi)) Arm Roll-In Pressure Sensor: No output (The control lever is in neutral.) NOTE: This control system is activated during combined operations (except for the arm roll-in combined operation). T2-2-46