hitachi — Valve Control

SYSTEM / Control System HSB Breaker Control (Optional) IMPORTANT: HSB breaker is set at breaker 1 of attachment mode in monitor unit when the machine is carried out. When breaker 3 to 5 is used, set the setting by using Dr. ZX. Operation: 1. When selecting breaker 1 in monitor unit, MC drives the selector valve control solenoid valve. 2. Pressure oil from the pilot pump flows through the selector valve control solenoid valve, shifts the selector valve, and the return circuit in breaker is connected to the hydraulic oil tank. 3. At the same time, MC drives the secondary relief control solenoid valve. 4.

Pressure oil from the pilot pump flows the secondary pilot relief pressure control solenoid valve, shifts the secondary pilot relief pressure control valve, and reduces relief set pressure in breaker circuit. 5. When the maximum pump 2 flow rate limit control solenoid valve is driven in the monitor unit, pump 2 flow rate can be adjusted finely. T1V5-05-01-111 T2-2-54