SYSTEM / Hydraulic System Pump Control Circuit (Refer to the Pump Device s e ction in COMPONENT OPERATION.) Pump Delivery Flow Rate Control by Flow Rate Control Pressure Pi The pilot pressure from control valve is selected by the shuttle valve in signal control valve so that the pump 1 flow control valve or pump 2 flow control valve in the signal control valve is shifted. Pilot pressure from the pilot pump is supplied to the regulator in pump 1 or pump 2 as flow rate control pressure Pi by shifting the pump 1 flow control valve or pump 2 flow control valve. NOTE:
When operating boom raise/ lower, arm roll-out/in, bucket roll-in/out and travel (right), flow rate control pressure Pi is supplied to main pump1. When operating boom raise, arm roll-out/in, swing right/left, auxiliary and travel (left), flow rate control pressure Pi is supplied to main pump 2. Pump Control (Speed Sensing) by Torque Control Solenoid Valve Pilot pressure from the pilot pump is controlled by the torque control solenoid valve and supplied to the regulator in pumps 1 and 2 as speed sensing pressure Ppc. T2-4-6