SYSTEM / Hydraulic System Valve Control Circuit (Refer to the Control Valve section in COMPONENT OPERATION.) Pilot pressure from the pilot valve, solenoid valve units (SC, SF, SG), flow combiner valve control spool (2) in the signal control valve, bucket flow control valve control spool (3) and arm flow control valve control spool (1) controls the valves below. Boom lower meter-in cut valve (7) controls boom flow control valve (6). (Refer to the Boom Lower Meter-In Cut.) Boom Lower Pilot Pressure: Boom Anti-Drift Valve (8) Arm Roll-In Pilot Pressure: Arm Anti-Drift Valve (16) Auxiliary Pilot Pressure:
Auxiliary Flow Combining Valve (20), Bypass Shut-Out Valve (10) (When the auxiliary spool is used.) Solenoid Valve Unit SC: Arm Regenerative Valve (12), Arm Flow Control Valve (Arm 2) (9) Solenoid Valve Unit SF: Digging Regenerative Valve (13) Solenoid Valve Unit SG: Main Relief Valve (19) (increasing the set-pressure) Auxiliary Flow Control Solenoid Valve: Auxiliary Flow Control Valve (18) (When the auxiliary spool is used.) Auxiliary Flow Combining Selection Solenoid Valve: Boom, Arm and Bucket Pilot Pressure Flow Combiner Valve Control Spool: Flow Combiner Valve (4) Bucket Flow Control Valve Control Spool: Bucket Flow Control Valve (5) Arm Flow Control Valve Control Spool:
Arm Flow Control Valve (Arm 1) (14) Positioning Lower Pilot Pressure (2-Piece Boom), Bypass Shut-Out Valve (10), Hose Rupture Valve (Optional) (15) Positioning Raise Pilot Pressure (2-Piece Boom), Bypass Shut-Out Valve (10) T2-4-8