hitachi — Charging Circuit (Key Switch: ON)

SYSTEM / Electrical System Alternator Operation The alternator consists of field coil FC, stator coil SC and diode D. The regulator consists of transistors (T1 and T2), Zener diode ZD and resistances (R1 and R2). Alternator terminal B is connected to base B of transistor T1 through the circuit [ B R RF (R) (R1) ] . When the battery relay is ON, the battery voltage is applied to base B of transistor T1 so that collector C is connected to emitter E. Therefore, field coil FC is grounded through transistor T1. At the beginning, no current is flowing through field coil FC. When the rotor starts rotating, alternate current is generated in stator coil SC by the rotor remanent magnetism.

When current flows through field coil FC, the rotor is further magnetized so that the generating voltage increases. Thereby, current flowing through field coil FC increases. Therefore, generating voltage increases further and the batteries start charging. Regulator Alternator B R L Battery Relay RF (R) R 3 R 4 R 5 D R 6 ZD R 2 Battery SC B R 1 C E FC D 1 T 2 B C E T 1 (F) E (E) T157-04-02-008 T2-5-14